APS mini Plus - Hardware
APS mini Plus hardware modules perform the pre-defined function which parameters can be set in a simple configuration program via PC. The modules can operate in standalone mode or as a part of small centrally managed system. Usually an RS 485/Ethernet converter (TCP/IP protocol) is being used for PC connection. After connecting the system to a PC, the access rights can be managed with a simple administration program and the operating events can be monitored.
Configurable operation parameters
Every module of the APS mini Plus can be configured with the APS Reader program. Following parameters can be set:
| Door control | |||
| Parameter | Value range | Factory default | |
| Door lock release time | 0 - 255 s | 7 s | |
|---|---|---|---|
| Door lock control setting | Direct / Reverse | Direct | |
| Door lock relay function setting | Standard / Toggle | Standard | |
| Permanent door lock release according to a time schedule | Never / Time schedule | Never | |
| Acoustic signal for door lock release | Yes / No | Yes | |
| Door ajar time | 0 - 255 s | 20 s | |
| Second input configuration | REX button / Handle | REX button | |
| Saving events in the memory | Door opened | Enabled / Disabled | Enabled |
| Door closed | Enabled / Disabled | Enabled | |
| Input 2 on | Enabled / Disabled | Enabled | |
| Input 2 off | Enabled / Disabled | Enabled | |
| Strike released | Enabled / Disabled | Enabled | |
| Strike closed | Enabled / Disabled | Enabled | |
| Alarm status signaling | |||
| Parameter | Value range | Factory default | |
| Tamper status signaling | 0 - 255 s | 30 s | |
| Forced door status signaling | 0 - 255 s | 30 s | |
| Door ajar signaling | 0 - 255 s | 0 s | |
| Other parameters | |||
| Parameter | Value range | Factory default | |
| Automatic summer time adjustment | Yes / No | Yes | |
| Door lock status indication (Yellow LED) | Yes / No | No | |
| Advanced function (ABA / WGD controllers, xRRF 12) | Yes / No | No | |
System reader modules
The system reader modules are equipped with all accessories to provide standard functions - door control (typically 2 inputs, 2 outputs, 3x LED, beeper, control logic) and ID media reading (according to a reader type). The reader modules are available in a comprehensive set of mechanical design, which is appropriate for various types of installation or for building in most often used designs of modular systems (e.g. bTicino, BPT entry panels, etc.). Most of the modules also feature contacts for detecting sabotage of a module.
Reader modules dispose of an alternative data output - WIEGAND protocol, which enables their usage in most of identification systems able to operate with reader modules with a standard WIEGAND interface. Reader's own function is reduced to ID reading and sending it to a superior system. The operating mode selection can be done by a user in the program APS Reader.
| APS mini Plus reader module properties | ||
| Property | meaning | |
| ID media reading - technology | EM Marin (125 kHz modules) | User identification |
|---|---|---|
| HID Proximity (125 kHz modules) | ||
| Dallas iButton (MRIF 232.IB) | ||
| Finger prints (MREF 63) | ||
| Inputs | Input 1 | Door status detection |
| Input 2 | REX button / handle contact | |
| Outputs | Output 1 | Door lock control |
| Output 2 | Alarm status indication | |
| RTC | Time schedules and holidays implementation | |
| Memory | Users | 748 + 2 ID |
| Time schedules | 64 time schedules | |
| Holidays | 64 holidays | |
| Events | minimally 2.000 operating events | |
| Tamper | Sabotage detection | |
| Signalization | Beeper | Identification events and alarms |
| Red LED | Communication with a PC status | |
| Green LED | Reading an ID media | |
| Yellow LED | Programming mode, change of PIN, door lock relay status | |
| Communication interface | RS 485 BUS | |
| TCP/IP (some modules) | ||
| Alternative data output | WIEGAND protocol (configurable) | |
Controllers
To connect reader modules using other ID technologies (incl. biometrics) there are functionally compatible controllers for connecting the modules with WIEGAND, ABA Track II or RS 232 interface at disposal. Controllers (interfaces), used for reader modules with WIEGAND and ABA Track II outputs connection, are provided in "double" implementation (for connection of 2 reader modules) and they dispose of a double amount of inputs, outputs, etc.
APS mini Plus system
System topology
APS mini Plus product catalogue