Client access / registration
- Home page
- Product lines
- Design
- Applications
- Software
- Product catalogue
- APS mini
- APS mini Plus
- Reader modules RFID 125 kHz
- Reader modules - other
- Single door controllers
- Dual door controllers
- Four-door controllers
- Controllers for elevator control
- Reader modules RFID 125 kHz, T & A
- Reader modules - other, T & A
- Single door controllers, T & A
- Dual door controllers, T & A
- Four-door controllers, T & A
- Controllers for elevator control, T & A
- T & A terminals
- APS 400
- Readers, ID media, others
- Software & licenses
- Locks
- Download
Contact
TECH FASS s.r.o.
Věštínská 1611/19
153 00, Prague
Czech Republic
tel.: +420 257 224 398
tel.: +420 257 224 399
e-mail: techfass@techfass.cz
MRIF 232-GP/TA
Ordering code: 53412602
The MRIF 232-GP/TA controller is used for connecting a GP8, GP20, GP30, GP60 or GP90 reader using its RS 232 interface to the APS mini Plus system. The module is designed for connection to the RS 485 BUS of the APS mini Plus identification system, where it occupies a single address. Up to 32 MRIF 232-GP/TA modules can be connected to a single communication line. The modules can be combined with other modules at a single communication line.
The module is designated for time & attendance applications.
The module is designed for a surface mounting in the outdoor non-protected environment.
MRIF 232-GP/TA data sheet
PDF document, 928 kB
MRIF 232-GP/TA leaflet
PDF document, 1586 kB
CE Conformity Declaration for MRIF 232-GP/TA
PDF document, 153 kB
| Mechanical design | |
| Weight | 0.202 kg |
|---|---|
| Operating temperature | -25°C ÷ +60°C |
| Humidity | Max. 95%, non-condensing |
| Housing | IP 65 |
| Environment | Outdoor unprotected |
| Dimensions | 65x165x55 mm |
| Reading technologies and licenses | |
| Events archive (MLE) | ![]() |
|---|---|
| Time & Attendance (MLA) | ![]() |
| Technical features | ||
| Supply voltage | 8 ÷ 15 VDC | |
|---|---|---|
| Current demand | Typical | 70 mA |
| Maximal | 130 mA | |
| Maximal length of reader’s wire | 10 m | |
| Real time clock | Yes, with self backup for 12 hrs. | |
| Memory | ID media | 748 ID, (2 master IDs optionally) |
| Events | 2,000 | |
| Time schedules | 64 | |
| Inputs | Door status | Logical potential-free contact |
| Exit button / Handle | Logical potential-free contact | |
| Outputs | Door lock | Relay NC/NO, 2A/24V |
| Alarm | Relay NC/NO, 2A/24V | |
| Indicators | LEDs on board for communication and I/O status indication | |
| Tamper protection | Integrated NC contact | |
| Communication interface | RS 485 for system BUS | |
| Addresses used at system BUS | 1 address | |
| HW address setting type | Address jumpers | |
| External device interface | 1x RS 232 input | |
| 1x external buzzer control interface | ||
| Alternative data output | WIEGAND (configurable) | |
| Special accessories | ||
| WIO 22 | 51901200 | Remote control relay module |
|---|---|---|